Water Quality Monitoring is a vital step towards saving energy costs at any facility that utilizes boilers. Recent research has shown that better control of parameters such such has water hardness, carbonate hardness and conductivity through online water quality monitoring can save facilities thousands of dollars in energy and down time costs. Water quality monitoring monitoring can also greatly increasethe functional life of a boiler, allowing for significant savings on capital equipment and investment.
Memeco Sales represents Heyl Brothers North America Water Analysis for monitoring:
Applications examples for low-pressure boilers include:
Applications for High-pressure boilers include:
Testomat 2000® monitors the water hardness for steam generators in Boiler houses, reverse osmosis plants, water treatment plants, etc. In addition the Testomat 2000® allows for a separate, quality-dependent softening to be installed via the use of external control units (e.g. Softmaster® MMP1 or Softmaster® MMP2). The simple conceptual design of the instrument also enables the measurement of other parameters in water, e.g. carbonate hardness, pvalues and minus-m values.
Due to its multifunctional design, the basic instrument can be adapted to numerous further requirements. The Range of the Testomat 2000® devices enables users to measure a variety of other parameters.
Testomat 2000® Ranges
Model/Type |
Measurement Parameters |
Measurement Range |
Applications/Functions |
Testomat 2000® | Water Hardness
Carbonate Hardness P-value Minus m-value |
0.05 – 2.5 *dH
0.5 – 20 *dH 1 – 15 mmol/l 0.5 – 0.5 mmol/l |
Universal application for waste water treatment plants
Approved for Boiler Houses |
Testomat 2000® Antox | Same as Testomat 2000® | Same as Testomat 2000® | Dosing of reducing agent |
Testomat 2000® CAL | Same as Testomat 2000® | Same as Testomat 2000® | With calibration function |
Testomat 2000® CLF | Free Chlorine | 0 – 2.5 mg/l | DPD method for swimming pools and drinking water |
Testomat 2000® CLT | Total Chlorine | 0 – 2.5 mg/l | DPD method for swimming pools and drinking water |
Testomat 2000® CrVI | Chromate
Chromium VI |
0 – 2.0 mg/l
0 – 1.0 mg/l |
Monitoring of process and waste water for electroplating |
Testomat 2000® Duo | Same as Testomat 2000® | Same as Testomat 2000® | Monitoring of two measuring points |
Testomat 2000® Fe | Iron II & Iron III | 0.1 -1.0 mg/l | De-ironing plants |
Testomat 2000® SO ₃ | Sulphite | 0 – 20 mg/l |
Monitoring of saturated oxygen due to sulphite in the boiler feed-water |
Testomat 2000®
Self clean |
Same as Testomat 2000® | Same as Testomat 2000® | Automatic measuring chamber cleaning |
Testomat 2000® THCL® | Total Chlorine
Water Hardness |
0.2.5 – mg/l
0.25 – 2.5 *dH |
DPD method for swimming pools and drinking water
Combination instrument for hardness and chlorine |
Testomat 2000® V | Water hardness
Carbonate hardness |
1.0 – 25.0* dH
1.0 – 20.0* dH |
Blending water |
Do you have an application you would like to consider?
Contact us today!